Ultraviolet climate resistance aging test box

  • ISO4892- 3. 2007( GB\T 16422 3- 1997) < product surface treatment Uv resistant climate ageing test>
  • Experiment condition:
    a Temperature range : RT+ 10- 70℃;
    b Temperature range : above 90% RH
    c Distance between test parts and modulator tube
    d Irradiation degree: UVA340 0. 68W/㎡
    e Irradiation time: black standard temperature 60℃ ± 3℃ , irradiation time: after 4 hours( plastic parts) 8hours( coating parts) , then under black standard temperature50℃±3℃ without irradiation 4 hours
  • Experiment result criteria:
    The surface of plastic parts or coating parts can not show color fading, color change orsurface layer come off